Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: ECG
Still deciding? Get samples of US$ 929/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2013-09-29
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485, FSC
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
  • Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
LTNA03
Certification
CE
Group
Female /Middle-Aged and Old /Male
Transport Package
Carton Box
Specification
40*32*25cm/1 pc, 4kg
Trademark
leytemed
Origin
China
HS Code
9018110000
Production Capacity
10000/Year

Product Description

 
Product Description

LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic

Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing DiagnosticLtna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing DiagnosticLtna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing DiagnosticLtna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing DiagnosticLtna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
LTNA03 Diagnostic Audiometer
This is an affordable, high-precision audiometer screening type. High-end hearing aids can be used when fitting hearing evaluation, and site services. Can also be used for schools, industrial and mining enterprises, Driving, rehabilitation centers and training for deaf children of hearing officers and other units to conduct rapid screening, carry convenient.  
Superior performance, easy operation and reliable quality.

Has the following test functions and features:
pure tone air conduction testing, a wide range of
provide continuous tone, pulse tone, warble tone
masking noise on the ears (narrowband noise)
Independent left and right channels
Built-in microphone to facilitate communication with patients
personalized key sound intensity output expansion, protection of patient hearing.
Optional bone conduction testing
Optional sound field test
Specifications
Channel: two independent signal channels and masking channel
Frequency: air conduction and free field 125-8000Hz; (bone conduction 250-6000Hz)
Masking: contralateral, narrowband noise
Intensity Range:
Air conduction

125 - 250 Hz -10 - 90HL
500 - 6000Hz -10 - 120HL
8000Hz -10 - 110HL
 Bone 500 - 4000Hz -10 - 70HL
Accuracy: sound intensity ± 3dB, frequency drift less than 1%
Distortion: less than 3% of the air conduction; bone less than 5%
Input interface: Response switch
Output interface: air conduction headphones, bone conduction earphone, free field
Standard features: pure tone audiometry continuous tone, pulse tone and warble tone
 Sound intensity step 5dB  Sound intensity extended
Communication with patients: a microphone built-in question (50-90dB adjustable)
Response in patients with light: there is
Data Transfer: None
Display: 2 line LCD LED
Power adapter: 230V AC adapter, 9V output
Volume weight: 270 x 200 x 80mm / 2.0 kg
Standard accessories: LY06 test headphones, transponders, AC adapter
Optional Accessories: B-71 bone conduction headset

LTNA03 Diagnostic Audiometer
Channel:Two independent signal channel and masking channel
Frequency: Air conduction and free sound field 125-8000Hz; (Bone conduction 250-6000Hz)
Masking: Pure tone test, white noise
Normal: Press INT to start sound stimulate
Inversion: Press INT to stop sound stimulate.5dB step and 5dB step continuous attenuation,1DB error.
Distortion: Air conduction: <2.5%; Bone conduction: <5%
Preheating time: Less than 10 minutes
Standard accessory: TDH39 Air conduction earphone, responder, power line
Sound pressure range
HZ AC BC
125 -10~90  
250 -10~100 -10~45
500 -10~120 -10~60
750 -10~120 -10~60
1000 -10~120 -10~70
1500 -10~120 -10~70
2000 -10~120 -10~70
3000 -10~120 -10~70
4000 -10~120 -10~60
6000 -10~110 -10~50
8000 -10~110  

Company Profile

Who we are ?
Leytemed is a global manufacturer and distributor ofall kinds medical products. We have more than

10+ years medical machine export experience.
Our Guangzhou Leyte Medical Equipment Co Ltd is a Leading supplier for LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic, Our main products include X-ray machine, B ultrasound scanners, Patient Monitor,ECG Machine,Syringe Pump,InfusionPump, patient monitor, ICU equipment, Lab equipment, and other related medical disposables. 

We have exported to more than 50 countries and built long term partnerships with clients of LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic.


Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic

Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
Our services: 
1. For all your inquires about us or our
 LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic, we will reply you in detail within 24 hours.

2. We own well-tranied and passional Sales & After- Sale Services who can speak fluent Engligh language.

3. 
We offer OEM services. Can print your own logo on LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic, can customize the retail box packing and other things. 

4. We have very 
experienced engineers ,can help you better use LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic. 


Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic
Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic

Delivery detail: 

1.We ship goods by 
UPS/DHL/FEDEX/TNT express takes 7~ 15 days to arrive , which is door to door ,you no need 
go out can get  LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic.

2.We can also help you ship 
by air cargo, it takes about 7~15days to arrive, while you need to go to Air port 
to take 
 LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic.


3.If goods are large quantity and you need not so urgently ,you can choose
 by sea to save some freight cost which takes you about one month to get  LTNA03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic, No matter what delivery way ,depending on your actual requirements.

Ltna03 Medical Diagnostic Audiometer for Hearing Aid Test Center Hearing Diagnostic

FAQ

Q: What's the minimum order quantity (MOQ)?
A: For most of our medical products, even order for
one unit is warmly welcomed.

Q: Can you do OEM/ODM private label?
A: Of course we can do
OEM/ODM private label for you.

Q: What's your delivery time?
A: Generally it is
3-5 days if the goods are in stock. if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction
by sea, by air or by express any way is ok for us.

Q: What is your terms of payment ?
A: We accept
T/T ,LC,Western Union ,Paypal and more. Please suggest your preferred payment method.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier