Customization: | Available |
---|---|
Classification: | ESR Analyzer |
Type: | ESR Analyzer |
Still deciding? Get samples of US$ 1547/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer
Technical specification:
Specifications 1) Display: 240 × 128 LCD display; 2) Printer: External inkjet printers; 3) Cuvette : 32ul/1cm titanium / quartz movement colorimetric cell; 4) Light source: 20W/12V quartz halogen tungsten lamp; 5) wavelength range (nm) :340-750; Detection range: -0.100 ~ 3.500; 6)5 filters ( 340, 405, 510, 546, 630 nm) 7) Output Resolution (A): 0.001; 8) detection temperature (°C): 25,30,37; 9) configured filter: 340,405,510,546,630, total up to 9 filters configuration; 10) Weight: 9 kg 11) Dimensions: 450mm×305 mm×185 mm Working principle and structure characteristic The equipment uses the infrared obstacle detection method, scan the tested blood regularly, and automatically detect the sub-interface of red cells and plasma from time to time. The tested data will be converted into results of Wechsler by computer processing. This can be displayed on the LCD screen or printer and can also be transmitted through the serial interface to a computer. The instrument makes up detection of the host (include infrared detection devices, computer control systems, thermal printer) and the adaptive power supply (SELV) . The instrument has the large display apparatus; the interface is simple appearance and has the film keyboard operation. The operation is simple and convenient. The instrument has highly automatic functions which can work at any time and continuously detect. The main performance indicators and the work of environmental requirements 1 Normal working conditions a)Relative humidity:≤70%; b)Away from strong sources of electromagnetic interference ; c)Prevent dust and vibration, air mustn't contain corrosive gases, pollution level 2 ; d)Power:220×(1±10 %)V,50×(1 ±2 %)Hz; e)Input power:40×(1+10%)VA; f)Environment with good grounding, transient over-voltage category of Class II; g)5-minute warm-up time boot. 2 Environmental conditions of storage and transportation (a)Ambient temperature range : -20ºC~+55ºC; (1) Relative humidity range: ≤93%; (2) Atmospheric pressure range : 500hpa~1060hpa; (3) No corrosive gas, a well-ventilated. 3 Basic parameters a) Test a sample bit: Instrument detection of up to 10 samples at the same time; b) The maximum detection rate: 20 samples / h; c) Blood sedimentation tube: After the State Drug Administration of the registered register vacuum,blood sedimentation tube φ8.3 * 120 vacuum tubes ( ordinary blood sedimentation tube) d) Sample size : blood drawing 1.60ml+ anticoagulant agent 0.4ml; e)The permissible error of adding the samples range:50mm ~ 64mm; f)Instrument readings resolution : ±0.1mm (results of Wechsler±1mm); g)Reading time interval :1 minute; h) Testing Time: 30 minutes, which is equivalent to 1 hour Wechsler; the testing time of equipment is 60 minutes, which is equivalent to two hours Wechsler; i) Display: 128x240 dot matrix LCD screen j) Power Supply: Instrument from an external 12V DC adapter power supply voltage (SELV); a) Outside measurement :310 x 190 x 180 (mm); l) Quality:4.8kg; 4 Technical requirements a)Testing range:0-140 mm/h(results of Wechsler); b)Testing relevance:Wechsler results of the linear correlation coefficient r≥0.98; c)Testing repetitive : CV < 3% ; 5 Main function a)Sample Adding Method : Insert the sample any time; detect the sample any time; b)The output of the results:Display and print samples' No. (serial number), Wechsler results and the whole process of erythrocyte sedimentation rate curve, detection time and temperature; when the instrument detection time is 60 minutes, it can automatically calculate, display and print Katz index; c)Instrument can choose the ambient temperature compensation. When selecting the function, when the room temperature is 18 ºC -30 ºC, it amends to 18 ºC according to the blood sedimentation calibration test results. (It can be selected in accordance with laboratory, the default of equipment is no compensated); d)Equipment can be stored not less than 150 samples of the test results, including the sample number (serial number), erythrocyte sedimentation rate values and the dynamic curve; e)There are power-off protection function, when a sudden power failure, automatic detection has been completed the tested results. f)Built-in thermal printer preparation equipment, it has automatic, manual printing options. g)Operation interface: Film keyboard operation; h)Communication Interface: RS-232 serial interface; |
Who we are ?
Leytemed is a global manufacturer and distributor ofall kinds medical products. We have more than
10+ years medical machine export experience.
Our Guangzhou Leyte Medical Equipment Co Ltd is a Leading supplier for LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer , Our main products include X-ray machine, B ultrasound scanners, Patient Monitor,ECG Machine ,SyringePump, InfusionPump,patient monitor, ICU equipment, Lab equipment, and other
related medical disposables.
We have exported to more than 50 countries and built long term partnerships with clients of LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer.
Our services:
1. For all your inquires about us or our LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer, we will reply you in detail within 24 hours.
2. We own well-tranied and passional sales & after- sale services who can speak fluent Engligh language.
3. We offer OEM services. Can print your own logo on LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer, can customize the retail box packing and other things.
4. We have very experienced engineers ,can help you better use LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer.
Delivery detail:
1.We ship goods by UPS/DHL/FEDEX/TNT express takes 7~ 15 days to arrive , which is door to door ,you no need
go out can get LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer .
2.We can also help you ship by air cargo, it takes about 7~15days to arrive, while you need to go to Air port to take LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer .
3.If goods are large quantity and you need not so urgently ,you can choose by sea to save some freight cost which takes you about one month to get LTCR01B Manufacturers ESR Analysis Instruments 20 Channel Lab ESR Analyzer, No matter what delivery way ,depending on your actual requirements.
Q: What's the minimum order quantity (MOQ)?
A: For most of our medical products, even order for only one unit is warmly welcomed.
Q: Can you do OEM/ODM private label?
A: Of course we can do OEM/ODM private label for you.
Q: What's your delivery time?
A: Generally it is 3-5 days if the goods are in stock. if the goods are not in stock, it is according to quantity.
Q: How to ship the order?
A: Please inform us your instruction by sea, by air or by express any way is ok for us.
Q: What is your terms of payment ?
A: We accept T/T ,LC,Western Union ,Paypal and more. Please suggest your preferred payment method.