Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer

Product Details
Customization: Available
Classification: ESR Analyzer
Type: ESR Analyzer
Still deciding? Get samples of US$ 938/Set
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2013-09-29
Management System Certification
ISO 9001, ISO 9000, GMP, ISO 13485, FSC
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
  • Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
LTCR02
Transport Package
Carton Packing
Specification
45*35*30cm, 8kg
Trademark
leytemed
Origin
China
HS Code
9027809900
Production Capacity
10000/Year

Product Description

Product Description

LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer 

 

Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate AnalyzerLtcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer

Technical specification:
Features
  1. Infrared optical detection technology
  2. Automatically scanning blood cells and location of the plasma interface from time to time with accurate positioning
  3. Internal thermal printer, ESR curve display and print-out
  4. Automatically amending the ESR results under the detecting temperature (15°C ~32°C)to the ESR values at 18°C, closely related with Westergren results
  5. The results are not interfered by high levels of hemoglobin, bilirubin or triglyceride
Technical Parameters
Measuring principle            Infrared barrier
Measuring time                30 minutes
Measuring precision            <0.2 mm
Reproducibility                < 3%
Temperature Precision                  <0.3°C
Sample volume                             <1.6mL whole blood anticoagulant
Reading channel                          10 
Display                                      LCD screen with back light
Interface                       RS-232 serial port
Print                          Internal thermal recorder
Operation conditions                          Temperature  15C°~32°C
Humidity  ≤85%
Power supply                    AC 220V/110V ±10%, 50/60 Hz
Dimension                                    320mm×260mm×158mm (L×W×H)
Net weight                                        5.0 kg


 
Company Profile

Who we are ?
Leytemed is a global manufacturer and distributor ofall kinds medical products. We have more than

10+ years medical machine export experience.
Our Guangzhou Leyte Medical Equipment Co Ltd is a Leading supplier for LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer , Our main products include X-ray machine, B ultrasound scanners, Patient Monitor,ECG Machine ,SyringePump, InfusionPump,patient monitor, ICU equipment, Lab equipment, and other 
related medical disposables. 

We have exported to more than 50 countries and built long term partnerships with clients of 
LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer  .

Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer

Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
Our services: 
1. For all your inquires about us or our
LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer , we will reply you in detail within 24 hours.
2. We own well-tranied and passional sales & after- sale services who can speak fluent Engligh language.
3. 
We offer OEM services. Can print your own logo on 
LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer , can customize the retail box packing and other things. 
4. We have very 
experienced engineers ,can help you better use 
LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer . 

Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer
Delivery detail: 
1.We ship goods by 
UPS/DHL/FEDEX/TNT express takes 7~ 15 days to arrive , which is door to door ,you no need 
go out can get
LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer.

2.We can also help you ship by air cargo, it takes about 7~15days to arrive, while you need to go to Air port to take LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer .

3.If goods are large quantity and you need not so urgently ,you can choose by sea to save some freight cost which takes you about one month to get LTCR02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer , No matter what delivery way ,depending on your actual requirements.

Ltcr02 Guangzhou Multi-Channel Erythrocyte Sedimentation Rate Analyzer

FAQ

Q: What's the minimum order quantity (MOQ)?
A: For most of our medical products, even order for only
one unit is warmly welcomed.

Q: Can you do OEM/ODM private label?
A: Of course we can do
OEM/ODM private label for you.

Q: What's your delivery time?
A: Generally it is
3-5 days if the goods are in stock. if the goods are not in stock, it is according to quantity.

Q: How to ship the order?
A: Please inform us your instruction
by sea, by air or by express any way is ok for us.

Q: What is your terms of payment ?
A: We accept
T/T ,LC,Western Union ,Paypal and more. Please suggest your preferred payment method.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier